Product Wiki · Recalls · EU Safety Gate (RAPEX)

Pizza pan — recall 0541/07

EU Safety Gate (RAPEX) · Germany · 2007-06-15 · Serious risk

Compiled from an official source — the facts on this page are reproduced from the issuing authority’s own published notice, which is linked on this page. No AI-generated text appears on this page. How we use AI →
Agency
EU Safety Gate (RAPEX)
Recall identifier
0541/07
Date of alert
2007-06-15
Country / jurisdiction
Germany
Risk level
Serious risk
Risk type
Electric shock
Brand
Diamant
Product category
Electrical appliances and equipment
Product type
Pizza pan
Reported risk: The product poses a serious risk of electric shock because :- the earth wire is not longer than the conductors carrying current. If the lead is pulled out of the plug housing, the earth wire does not break only after the conductors carrying current; it is therefore ineffective;- the cross-section of the mains connection lead is too small (only 0.75 mm²). The cross-section must be at least 1 mm² for appliances with a rated current of 6.5 A;- the appliance is not equipped with a pull-relief device, with the result that the conductors are not protected from pulling, including twisting, at the point at which they are connected inside the appliance and the insulation is protected against abrasion. This results in a risk of electric shock;- the screw intended to secure the earth connection is not protected against accidentally coming loose. Earth clamps must be protected against accidentally coming loose.This product does not comply with the Low Voltage Directive and the relevant standards.
Action taken by the authority
Type of economic operator taking notified measure
Other
Category of measure
Voluntary withdrawal from the market by the retailer
Primary source: https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/-12246

Verify each fact at the issuing agency before acting. Recall scope, affected lots, and remediation instructions may be updated by the agency after our last sync.

ProductGuru indexes recall and safety-alert records from ~30 public agency registries. We are not lawyers, regulators or product-safety consultants. This page restates what the named agency published; consult the primary source above (or qualified counsel in your jurisdiction) before any commercial, medical or safety decision.