EU Safety Gate (RAPEX) · Finland · 2007-12-14 · Serious risk
🏛Compiled from an official source — the facts on this page are reproduced from the issuing authority’s own published notice, which is linked on this page. No AI-generated text appears on this page. How we use AI →
Reported risk: This product poses a risk of electric shock due to the fact that there is not sufficient electrical insulation between the primary circuit connected to the mains and the secondary circuit that can be touched. The secondary circuit is accessible through the terminals. Creepage distances and clearances in the mains transformer between the primary windings and secondary windings, between the primary windings and the output winding wires of the secondary windings, between the secondary windings and output winding wires of the primary windings are less than 5 / 4 mm (measured a minimum 0.45 mm / 3.5 mm / 1.7 mm). The secondary circuit is accessible through the terminals. The windings are positioned concentrically on a single coil former. All output winding wires are not insulated with the insulation tubes.The product does not comply with the Low Voltage Directive.
Action taken by the authority
Type of economic operator to whom the measure were ordered
Verify each fact at the issuing agency before acting. Recall scope, affected lots, and remediation instructions may be updated by the agency after our last sync.
ProductGuru indexes recall and safety-alert records from ~30 public agency registries. We are not lawyers, regulators or product-safety consultants. This page restates what the named agency published; consult the primary source above (or qualified counsel in your jurisdiction) before any commercial, medical or safety decision.