Panorama HFO

Health Canada — Medical Devices · 2023-11-30 · CanadaType I
Issuing authority
Health Canada — Medical Devices
Published
2023-11-30
Country of alert
Canada
Alert level
Type I
Alert type
recall

What the authority reported

Philips has been informed of an event in which the structural integrity of the Panorama 1.0T HFO system components failed due to unintended excessive pressure buildup of helium gas during a magnet quench. During a quench, a large amount of helium evaporates and is vented outside the building through a venting system. If an unknown blockage is present in the venting system and the pressure exceeds design limits, the structural integrity of the system may be compromised. The magnet may experience an unsolicited quench during normal use or will quench when initiated in an emergency situation by the operator pressing the magnet emergency stop button. Philips has received one (1) complaint of system and property damage after quenching the magnet on Panorama 1.0T systems as of November 2023. There was no report of injury or serious harm. Philips received a complaint on October 3rd, 2023 regarding a quench that occurred on a Panorama 1.0T system on October 2nd, 2023. The system was about to be decommissioned. It was decided that the magnet would be quenched to remove the magnetic field as part of decommissioning. The quench was triggered via the emergency magnet off/ERDU (emergency run down unit) button. After the button was pressed, involved persons went outside the building to observe the helium vent exit for a plume coming out. Upon return to the exam room the system and its environment was found to have sustained damage. Recall Start Date: October 3, 2023

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: Health Canada — Medical Devices — official record →
Record last checked against the registry on 2026-05-31.

More recalls: Health Canada — Medical Devices · Canada · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.