Small transformer for household (Transformer and voltage regulator) (ref K23/EP/00014)

OECD GlobalRecalls — KR · 2023-06-28 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2023-06-28
Country of alert
Korea (Republic of)

What the authority reported

Inadequate temperature rise - T1 Coil (198V): 114.4 ℃ / T1 Core (198V): 114.0 ℃ - T1 Coil (233V): 154.5 ℃ / T1 Core (233V): 128.4 ℃ - Allowable level: 110 ℃ - 1st internal cable (198V): 93.1 ℃ / 2nd internal cable (198V): 76.9 ℃ - 1st internal cable (233V): 117.5 ℃ / 2nd internal cable (233V): 98.2 ℃ - Allowable level: 70 ℃; Insufficient labelling - Different model name: (At the approval) LD-100D, (Product) 100VA - Transformer type, Class II appliances, Indoor-only symbol missing - Class II transformer symbol missing ◇ Risk of electric shock and burns if the temperature exceeds the standard temperature ◇ Risk of providing wrong information

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-11-10.

More recalls: OECD GlobalRecalls — KR · Korea (Republic of) · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.