Official recall record
LED lighting (Lighting) (ref K23/EP/00032)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2023-09-21
- Country of alert
- Korea (Republic of)
What the authority reported
Inadequate creepage distance and clearance distance - Between live parts and the surface attached (Measured value of creepage distance) 1.63 mm / (Allowable level) 5 mm or over (Measured value of clearance distance) 1.63 mm / (Allowable level) 3 mm or over; Inadequate dielectric strength - Failed to withstand at AC 2,880 V; Insufficient labelling - Class II appliance symbol (IEC 60417-5172(2003-02)) missing ◇ Risk of electric shocks if conductive parts are touched when insulation distance is short ◇ Risk of electric shock due to insulation breakdown ◇ Risk of providing wrong information
What to do
Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.
Record last checked against the registry on 2026-11-10.