Official recall record
DC power supply (DC power supply) (ref K23/EP/00036)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2023-12-12
- Country of alert
- Korea (Republic of)
What the authority reported
Inadequate creepage distance and clearance distance - Insufficient creepage distance and clearance distance between primary (EC3) – secondary (output terminal pattern) - Clearance distance: (Measured value) 2.10 mm / (Standard) 4.0 mm or above - Creepage distance: (Measured value) 2.10 mm / (Standard) 4.0 mm or above; Insufficient labelling – After the voltage’s rating, there is no information about the type of supply voltage (~) ◇ Risk of electric shock if surface is touched ◇ Risk of electric shocks if conductive parts are touched when insulation distance is short ◇ Risk of providing wrong information
What to do
Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.
Record last checked against the registry on 2026-10-20.