Electric heated massage device (Foot heater that uses DC power)

OECD GlobalRecalls — KR · 2023-12-12 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2023-12-12
Country of alert
Korea (Republic of)

What the authority reported

Inadequate temperature rise - Heating element: (Measured value) 122.0 ℃ / (Standard) 120 ℃ or below - Surface: (Measured value) 101.2 ℃ / (Standard) 85 ℃ or below; Inadequate input and current - (Rated) 3 W - (Measured value) 4.05 W (+35 %) / (Standard) +20 %; Insufficient labelling - Class III appliance symbol (IEC 60417-5180) missing ◇ Risk of burns if exposed to body for an extended time ◇ Risk of providing wrong information

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-10-20.