ProductGuru Recalls

Official recall record

Safety helmet for bicycle (Safety helmet for exercise)

OECD GlobalRecalls — KR · 2023-08-09 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2023-08-09
Country of alert
Korea (Republic of)

What the authority reported

Maximum acceleration has exceeded the allowable level for shock absorption - Measured value: ①High-temp 3847 m/s2, ②Low-temp 5134 m/s2, ③Water soaking 4020 m/s2, ④Aging 3626 m/s2 - Allowable level: 2943 m/s2 or below ◇ Risk of serious injuries in the body including head while using the product

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-11-10.

More recalls: OECD GlobalRecalls — KR · Korea (Republic of) · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.