Power supply for computers (Power supply for computers) (ref K24/EP/00005)

OECD GlobalRecalls — KR · 2024-02-29 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2024-02-29
Country of alert
Korea (Republic of)

What the authority reported

Inadequate creepage distance and clearance distance - (Standard) At least two layers of insulation taping shall be applied between the primary and the secondary of the transformer(T2)’s inside - (Measured value) Only a single layer of insulation taping is applied between the primary and the secondary of the transformer(T2)’s inside ◇ Risk of electric shock if the surface is touched