Cable reel (Parts and fittings for electrical system) (ref K24/EP/00009)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2024-02-29
- Country of alert
- Korea (Republic of)
What the authority reported
Inadequate temperature rise - (Standard) The overload protection device shall not be activated at the temperature rise test - (Result) The overload protection device activated at the elongation test; Inadequate protection against electric shock - (Standard) When the test finger is applied at any possible place with a force of 1N, it shall contact the live parts - (Result) It contacted the live parts of the cable reel’s outlet o Insufficient labelling - Manufacturing year and month missing ◇ Risk of fire during normal use due to excessive temperature rise ◇ It poses a potential risk that a user could mistakenly touch the power and ends up getting unwanted electric shocks