Plug and outlet (Parts and fittings for electrical system) (ref K24/EP/00010)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2024-02-29
- Country of alert
- Korea (Republic of)
What the authority reported
Inadequate temperature rise - (Standard) The temperature of an electrical terminal shall not exceed the allowable level of 45K - (Measured value) Maximum 47.9 K(L-N connection), maximum 92.3 K(L-E connection); Inadequate terminal and permanently fixed terminal - Connection between terminals missing (Connection between plug receptacle and switch, connection between ground terminals) o Insufficient labelling - Manufacturing year and month missing ◇ Risk of fire during normal use due to excessive temperature rise