Official recall record
Bill counter (Bill counter)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2024-09-11
- Country of alert
- Korea (Republic of)
What the authority reported
Inadequate creepage distance and clearance distance - Inadequate clearance distance between the primary side and the secondary side: (Measured value) 2.5 mm, (Allowable level) 3.0 mm or over - Inadequate creepage distance between the primary side and the secondary side: (Measured value): (Measured value) 2.5 mm, (Allowable level) 5.0 mm or over; Labelling - Inadequate labelling for protective bonding cable terminal : No label for grounding ◇ Risk of electric shock if surface is touched ◇ Risk of providing wrong information
What to do
Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.