ProductGuru Recalls

Official recall record

Plug and outlet (Electrical parts and connectors) (ref K25/EP/00010)

OECD GlobalRecalls — KR · 2025-02-27 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2025-02-27
Country of alert
Korea (Republic of)

What the authority reported

Inadequate temperature rise - (Measured) L-E connection 56K, L-N connection 68.1 (Allowable level) 45K or below; Inadequate protection against electric shock - (Result) 1N test gauge made contact with the charging part during the test. - (Standard) For outlets equipped with a shutter, neither the 20N nor 1N test gauge should make contact with the charging part. ◇ Risk of product-caused fire if the temperature exceeds the standard temperature ◇ Risk of short circuit and excessive temperature rise due to loose terminal contact if the product is used for a long time or aged

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-10-20.

More recalls: OECD GlobalRecalls — KR · Korea (Republic of) · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.