ProductGuru Recalls

Official recall record

Plug and Socket (Accessories and Connection Components for Electrical Installations)

OECD GlobalRecalls — KR · 2025-07-17 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2025-07-17
Country of alert
Korea (Republic of)

What the authority reported

Temperature Rise Non-compliance -(Measured) L-N test 76.2 K, L-E test 46.8 K, (Standard) 45 K or less * Related Standard: KC 60884-1, 19. Temperature Rise Terminal and Fixed Terminal Non-compliance -(Measured) No Permanent Connection -(Standard) Non-replaceable connection mechanisms should have soldering, welding, crimping, or permanent connection (termination) with the same effect * Related Standard: KC 60884-1, 12. Terminal and Fixed Terminal There is a risk of product fire if the standard temperature is exceeded Long-term use and aging may cause terminal looseness, leading to short circuit and excessive heat

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-10-20.

More recalls: OECD GlobalRecalls — KR · Korea (Republic of) · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.