Official recall record
Plug and Socket (Electric Installations Accessories and Connecting Devices)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2025-07-17
- Country of alert
- Korea (Republic of)
What the authority reported
1. Noncompliance with temperature rise - (Measured) L-N Test 56.1 K (Standard) 45 K or less * Related Standard: KC 60884-1, 19. Temperature rise 2. Incomplete labeling - Omission of model name (Model name does not appear when checking certification number) 1. There is a risk of product fire when the standard temperature is exceeded. 2. There is a concern of providing incorrect information.
What to do
Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.
Verify at the source:
OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-10-20.
Record last checked against the registry on 2026-10-20.
ProductGuru Recalls republishes official safety information with attribution. We are not
the issuing authority and this page is not advice. If this product is a medical device or
medication, speak to a doctor or pharmacist. Found an error?
Report it — corrections are published.