ProductGuru Recalls

Official recall record

Plug and Socket (Accessories and Connectors for Electrical Installations)

OECD GlobalRecalls — KR · 2025-07-17 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2025-07-17
Country of alert
Korea (Republic of)

What the authority reported

- Non-compliance with temperature rise - (Measured) L-N test 65.0K, L-E test 57.6K (Standard) 45K or less * Related standard: KC 60884-1, 19. Temperature Rise - Non-compliance with terminal and permanently fixed terminal - (Measured) No permanent connection - (Standard) Non-exchangeable code connection devices must have a permanent connection (termination) such as soldering, welding, mechanical fixing, or an equivalent effect * Related standard: KC 60884-1, 12. Terminal and Permanently Fixed Terminal - Risk of product fire if the standard temperature is exceeded - Long-term use and aging of the product may cause terminal loosening, leading to short circuits and excessive temperature

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-10-20.

More recalls: OECD GlobalRecalls — KR · Korea (Republic of) · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.