Plug and Socket (Accessories and Connectors for Electrical Installations)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2025-07-17
- Country of alert
- Korea (Republic of)
What the authority reported
- Non-compliance with temperature rise - (Measured) L-N test 65.0K, L-E test 57.6K (Standard) 45K or less * Related standard: KC 60884-1, 19. Temperature Rise - Non-compliance with terminal and permanently fixed terminal - (Measured) No permanent connection - (Standard) Non-exchangeable code connection devices must have a permanent connection (termination) such as soldering, welding, mechanical fixing, or an equivalent effect * Related standard: KC 60884-1, 12. Terminal and Permanently Fixed Terminal - Risk of product fire if the standard temperature is exceeded - Long-term use and aging of the product may cause terminal loosening, leading to short circuits and excessive temperature
What to do