Official recall record
Battery (Only Rechargeable Batteries)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2025-12-11
- Country of alert
- Korea (Republic of)
What the authority reported
External short circuit and overcharge test failed 1. External short circuit test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Charge conditions: 0.2C(1,000 mA), 4.2 V, 0.05 C cut-off(100 mA) ※ External short circuit test start conditions: 22.7 ℃, 82.62 mΩ, Battery OCV 4.104 V ※ Maximum temperature rise of the battery: 23.9 ℃ 2. Overcharge test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Overcharge test conditions: 6.0 V, 10.0 A (2.0 * 5,000 mA) Battery OCV 3.466 V ※ Maximum temperature rise of the battery: 32.9 ℃; Risk of inflammation or explosion due to overheating when an overcurrent flows; Risk of inflammation and explosion exists
What to do
Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.
Record last checked against the registry on 2026-10-20.