ProductGuru Recalls

Official recall record

Battery (Only Rechargeable Batteries)

OECD GlobalRecalls — KR · 2025-12-11 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2025-12-11
Country of alert
Korea (Republic of)

What the authority reported

External short circuit and overcharge test failed 1. External short circuit test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Charge conditions: 0.2C(1,000 mA), 4.2 V, 0.05 C cut-off(100 mA) ※ External short circuit test start conditions: 22.7 ℃, 82.62 mΩ, Battery OCV 4.104 V ※ Maximum temperature rise of the battery: 23.9 ℃ 2. Overcharge test: Battery ignition (PCB) ※ Discharge conditions: 0.2C(1,000 mA), 3.0 V ※ Overcharge test conditions: 6.0 V, 10.0 A (2.0 * 5,000 mA) Battery OCV 3.466 V ※ Maximum temperature rise of the battery: 32.9 ℃; Risk of inflammation or explosion due to overheating when an overcurrent flows; Risk of inflammation and explosion exists

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-10-20.

More recalls: OECD GlobalRecalls — KR · Korea (Republic of) · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.