ProductGuru Recalls

Official recall record

Power supply unit for computers (power supply unit for computers) (ref K26/EP/10023021)

OECD GlobalRecalls — KR · 2026-10-29 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2026-10-29
Country of alert
Korea (Republic of)

What the authority reported

(Critical defect) 1. Inadequate clearance and creepage distance. - Insufficient insulation distance between primary (L) and earth. - Measured clearance distance: 1.90 mm (Standard limit: 2.0 mm or more). - Measured creepage distance: 1.90 mm (Standard limit: 2.5 mm or more).; If the insulation distance is insufficient, there is a risk of electric shock when a person touches live parts.

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OECD GlobalRecalls — KR — official record →
Record last checked against the registry on 2026-11-10.

More recalls: OECD GlobalRecalls — KR · Korea (Republic of) · all filters

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.