Portable laser product (portable laser product)

OECD GlobalRecalls — KR · 2026-07-23 · Korea (Republic of)
Issuing authority
OECD GlobalRecalls — KR
Alert date
2026-07-23
Country of alert
Korea (Republic of)

What the authority reported

- Laser class exceeded the standard limit. - Cross beam measured value: 2.55 mW (Condition 3), standard limit: less than 1 mW. - Non-compliance with labelling requirements. - Date of manufacture, importer’s address and telephone number not indicated. - Warning label not provided. - In the instruction manual, the warning label design and attachment position explanation, the explanation of the laser emission location, and the cautionary statement to follow the instructions are omitted. - Risk of visual impairment. - Concern about provision of incorrect information.