Official recall record
Swim aid (wearable) (water play equipment)
- Issuing authority
- OECD GlobalRecalls — KR
- Alert date
- 2026-07-23
- Country of alert
- Korea (Republic of)
What the authority reported
- Safety non-compliance of buckles and other attachments. - Part: buckle. - Measured value: 36 N. - Standard limit: 50 N or more. - Insufficient strength at the joint section and inadequate durability of the auxiliary component for air inflation. - Measured result: air leakage occurred. - Standard requirement: When alternately inflating the airbag, there must be no air leakage. - There is a risk of drowning if the buckle releases during use. - There is a risk of drowning if air escapes from the product during use.