What the authority reported

The product failed the electric strength test as the insulation between the input and output circuits broke down when a 2.92 kV test voltage was applied between the circuits. A breakdown in clearances and insulation can lead to overheating and/or electric shock. The shutter featured on the sockets did not restrict access to live parts. As the power strip accepts BS1363 plugs, it is required to have a rated current of 13A, however, was found to only have 10A. Excessive loads can lead to overheating and fire. Some of the required documentation and markings were not present. The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

What to do

Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.

Verify at the source: OPSS (UK) — official record →
Record last checked against the registry on 2026-06-05.

More recalls: OPSS (UK) · United Kingdom · all filters

Other recalls from this brand

ProductGuru Recalls republishes official safety information with attribution. We are not the issuing authority and this page is not advice. If this product is a medical device or medication, speak to a doctor or pharmacist. Found an error? Report it — corrections are published.