Official recall record
Série 2 (G42) - Série 3 (G20; G21; G28)
- Issuing authority
- EU Safety Gate (RAPEX)
- Alert date
- 2026-02-20
- Country of alert
- France
- Alert level
- Serious risk
- Risk type (official)
- Fire
- Brand on record
- Bmw
What the authority reported
The failure concerns the RSW22 starter, type RWT (reinforced for watertightness). Increased abrasion of the magnetic contact can lead to the formation of deposits at the lowest point of the relay interior. This in turn can increase the resistance of the relay contact, causing accidental ignition or even short circuits, possibly leading to a thermal reaction and fire.
What to do
Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.