Official recall record
Mosquito lamp with USB charger Moskītu lampa ar U
- Issuing authority
- EU Safety Gate (RAPEX)
- Alert date
- 2026-04-10
- Country of alert
- Latvia
- Alert level
- Serious risk
- Alert type
- Chemical, Environment
- Barcode (EAN/GTIN)
- 4752214010783
- Brand on record
- Kurši
What the authority reported
The solders in the product have an excessive concentration of lead (measured values up to 40% by weight respectively). The plastic material of the cable has an excessive concentration of DEHP (measured values up to 0.18% by weight respectively). Lead poses a risk to the environment. DEHP and DBP may harm the health by causing possible damage to the reproductive system and to the environment. The product does not comply with the requirements of the Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS 2 Directive) nor with the European standard 62321-1.
What to do
Follow the instructions in the official notice — recall remedies (refund, repair, replacement, or disposal) are defined by the issuing authority and the responsible business, and they differ per recall. Do not rely on summaries, including this one.
Record last checked against the registry on 2026-09-08.